Which of the following factors determine the characteristic impedance of a parallel conductor feed line?
Show the answer and why
Answer A. The distance between the centers of the conductors and the radius of the conductors
The characteristic impedance of a parallel conductor feed line depends on the spacing between the conductor centers and the radius of the conductors.
Describe this graphic in words
Three panels. Coax has a center conductor, insulation and a shield, and is 50 or 75 ohms. Parallel conductor lines have two wires, and their impedance depends on the spacing between the conductors and their radius; window line is 450 ohms. A graph shows loss in decibels per 100 feet rising with frequency. A note says characteristic impedance comes from geometry, not length or frequency.
This is a teaching note. Characteristic impedance is set by the geometry of the line, not by its length or the frequency. For open-wire or ladder line, closer spacing gives a lower impedance and a larger conductor radius also gives a lower one.
Why the other choices are wrong
- B. Line length does not change the characteristic impedance.
- C. Frequency does not change the characteristic impedance of an ideal line.
- D. Neither frequency nor length sets the characteristic impedance.