ARSC Tech School

Amateur Extra E7D: Power supplies and voltage regulators

599 questions · pool July 1, 2024 to June 30, 2028 · the exam has 50 questions; 37 to pass

E7 · PRACTICAL CIRCUITS

Power supplies and voltage regulators; solar array charge controllers

15 questions in group E7D

One question from this group appears on each exam.

E7D01

How does a linear electronic voltage regulator work?

Show the answer and why

Answer D. The conduction of a control element is varied to maintain a constant output voltage

A linear regulator varies how hard a control element conducts to keep the output voltage constant.

Series and shunt linear regulators compared, with a worked pass-element dissipation and dropout example.
Describe this graphic in words

Two block diagrams compare linear regulators. The series regulator has a pass element in the path to the load, controlled by an error amplifier and a reference. The shunt regulator has a series resistor and a shunt element across the load that loads the source. Two panels below show that a series regulator with 13.8 volts in, 5 volts out and 1 amp dissipates 8.8 watts, and that a 5 volt regulator with 1 volt dropout needs at least 6 volts in.

This is a teaching note. It compares the output with a stable reference and adjusts the pass transistor to compensate for changes in input voltage or load. Whatever voltage is not needed is dropped across the transistor as heat.

It is continuously conducting, not switching. Duty cycle belongs to switchmode designs.

Why the other choices are wrong

  • A. The output is a steady DC level, not a ramp.
  • B. It relies on a pass element.
  • C. A duty cycle proportional to line or load describes a switching regulator.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D02

How does a switchmode voltage regulator work?

Show the answer and why

Answer B. By varying the duty cycle of pulses input to a filter

A switchmode regulator varies the duty cycle of pulses input to a filter.

Switchmode regulator block diagram with pulse waveform, and why high frequency makes it smaller.
Describe this graphic in words

A block diagram shows DC input feeding a switch, then an L-C filter that averages the pulses into smooth DC output, with a control block adjusting the pulse width from a sample of the output. A pulse train with a dashed average line shows that wider pulses raise the output. Two cards compare a 60 hertz linear supply with large parts against a switching supply at tens to hundreds of kilohertz with much smaller parts.

This is a teaching note. It chops the DC input into pulses, and the filter (an inductor and capacitor) averages them into a smooth output. A control circuit changes the pulse width to hold the output constant.

Since the switch is fully on or off, little power is wasted.

Why the other choices are wrong

  • A. The output stays one polarity.
  • C. Varying the conductivity of a pass element is a linear regulator.
  • D. Switching between two Zener voltages is not how switchmode regulators work.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D03

What device is used as a stable voltage reference?

Show the answer and why

Answer A. A Zener diode

A Zener diode provides a stable voltage reference.

Figure E7-2 redrawn: Q1 is a series pass transistor, D1 a Zener reference, C2 bypasses ripple, and it is a linear regulator.
Describe this graphic in words

A linear voltage regulator redrawn from +25 volts in to +12 volts out. Q1 is a gold-ringed series pass transistor with its collector on the input and emitter on the output. Its base is held by Zener diode D1 to ground and fed from the input through R1. C2 in parallel with D1 is outlined in gold and bypasses ripple. Text below names each part role.

This is a teaching note. When reverse biased beyond its breakdown voltage, a Zener holds nearly constant voltage across it over a wide range of current. That is exactly what a reference needs.

An SCR is a latching switch, and A/D and D/A converters are data converters, not references.

Why the other choices are wrong

  • B. A D/A converter converts digital values to analog.
  • C. An SCR is a thyristor used for switching.
  • D. An A/D converter digitizes a signal.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D04

Which of the following describes a three-terminal voltage regulator?

Show the answer and why

Answer B. A series regulator

A three-terminal regulator such as a 7805 is a series regulator.

Series and shunt linear regulators compared, with a worked pass-element dissipation and dropout example.
Describe this graphic in words

Two block diagrams compare linear regulators. The series regulator has a pass element in the path to the load, controlled by an error amplifier and a reference. The shunt regulator has a series resistor and a shunt element across the load that loads the source. Two panels below show that a series regulator with 13.8 volts in, 5 volts out and 1 amp dissipates 8.8 watts, and that a 5 volt regulator with 1 volt dropout needs at least 6 volts in.

This is a teaching note. It has an input, output and ground pin, and inside it a pass transistor sits in series between input and output.

A shunt regulator is connected across the load and bleeds off excess current, as a Zener does. Current sources are a different function.

Why the other choices are wrong

  • A. It regulates voltage, not current.
  • C. A shunt regulator sits across the load.
  • D. It is not a shunt current source.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D05

Which of the following types of linear voltage regulator operates by loading the unregulated voltage source?

Show the answer and why

Answer D. A shunt regulator

A shunt regulator works by loading the unregulated source.

Series and shunt linear regulators compared, with a worked pass-element dissipation and dropout example.
Describe this graphic in words

Two block diagrams compare linear regulators. The series regulator has a pass element in the path to the load, controlled by an error amplifier and a reference. The shunt regulator has a series resistor and a shunt element across the load that loads the source. Two panels below show that a series regulator with 13.8 volts in, 5 volts out and 1 amp dissipates 8.8 watts, and that a 5 volt regulator with 1 volt dropout needs at least 6 volts in.

This is a teaching note. The regulating element is connected in parallel with the load and draws more or less current so the series dropping resistor drops the right amount of voltage.

A series regulator instead sits in the path to the load and does not load the source in the same way.

Why the other choices are wrong

  • A. A constant current source does not regulate voltage by shunting.
  • B. A series regulator sits in the path to the load.
  • C. A shunt current source is not a standard regulator type.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D06

What is the purpose of Q1 in the circuit shown in Figure E7-2?

Figure E7-2. A schematic of a voltage regulator. A plus 25 volt input has capacitors C1 and C2 and resistor R1. Transistor Q1 passes current to a plus 12 volt output that has capacitor C3 and load resistor R2. A zener diode D1 connects the transistor's base to ground.
Show the answer and why

Answer C. It controls the current to keep the output voltage constant

Q1 controls the current to keep the output voltage constant.

Figure E7-2 redrawn: Q1 is a series pass transistor, D1 a Zener reference, C2 bypasses ripple, and it is a linear regulator.
Describe this graphic in words

A linear voltage regulator redrawn from +25 volts in to +12 volts out. Q1 is a gold-ringed series pass transistor with its collector on the input and emitter on the output. Its base is held by Zener diode D1 to ground and fed from the input through R1. C2 in parallel with D1 is outlined in gold and bypasses ripple. Text below names each part role.

This is a teaching note. In Figure E7-2 the +25 V input feeds the collector of Q1, its emitter goes to the +12 V output, and its base is held by Zener diode D1. Q1 is the series pass transistor: it conducts more or less so the emitter stays about a base-emitter drop below the Zener voltage.

It is not switching or chopping, because it conducts continuously.

Why the other choices are wrong

  • A. An emitter follower does have some built-in negative feedback, but that is a side effect. The job the figure shows for Q1 is passing and controlling the load current to hold the output.
  • B. It is in series, not a constant load.
  • D. Chopping the DC is how a switching regulator works.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D07

What is the purpose of C2 in the circuit shown in Figure E7-2?

Figure E7-2. A schematic of a voltage regulator. A plus 25 volt input has capacitors C1 and C2 and resistor R1. Transistor Q1 passes current to a plus 12 volt output that has capacitor C3 and load resistor R2. A zener diode D1 connects the transistor's base to ground.
Show the answer and why

Answer A. It bypasses rectifier output ripple around D1

C2 bypasses rectifier output ripple around D1.

Figure E7-2 redrawn: Q1 is a series pass transistor, D1 a Zener reference, C2 bypasses ripple, and it is a linear regulator.
Describe this graphic in words

A linear voltage regulator redrawn from +25 volts in to +12 volts out. Q1 is a gold-ringed series pass transistor with its collector on the input and emitter on the output. Its base is held by Zener diode D1 to ground and fed from the input through R1. C2 in parallel with D1 is outlined in gold and bypasses ripple. Text below names each part role.

This is a teaching note. In Figure E7-2, R1 feeds the Zener D1 and the base of Q1 from the +25 V input, and C2 (4000 uF) sits from that junction to ground in parallel with D1. It shunts any ripple on the Zener reference to ground so the base voltage stays smooth.

It is not the main input filter (that is C1) and it does not provide the bias; R1 and D1 do that.

Why the other choices are wrong

  • B. The brute force filter is the large input capacitor, not C2.
  • C. It is not an anti-oscillation part.
  • D. Bias comes from the Zener voltage, not from C2.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D08

What type of circuit is shown in Figure E7-2?

Figure E7-2. A schematic of a voltage regulator. A plus 25 volt input has capacitors C1 and C2 and resistor R1. Transistor Q1 passes current to a plus 12 volt output that has capacitor C3 and load resistor R2. A zener diode D1 connects the transistor's base to ground.
Show the answer and why

Answer C. Linear voltage regulator

The circuit shown in Figure E7-2 is a linear voltage regulator.

Figure E7-2 redrawn: Q1 is a series pass transistor, D1 a Zener reference, C2 bypasses ripple, and it is a linear regulator.
Describe this graphic in words

A linear voltage regulator redrawn from +25 volts in to +12 volts out. Q1 is a gold-ringed series pass transistor with its collector on the input and emitter on the output. Its base is held by Zener diode D1 to ground and fed from the input through R1. C2 in parallel with D1 is outlined in gold and bypasses ripple. Text below names each part role.

This is a teaching note. Figure E7-2 shows a pass transistor Q1 in series between the +25 V input and the +12 V output, a Zener D1 on its base, and filter capacitors, with no inductor or switching drive. That is a series linear regulator.

It has no signal input or output coupling, so it is not an amplifier.

Why the other choices are wrong

  • A. A switching regulator needs a switching element and inductor.
  • B. It is a regulator, not a common emitter amplifier.
  • D. It is not a common base amplifier.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D09

How is battery operating time calculated?

Show the answer and why

Answer C. Capacity in amp-hours divided by average current

Battery operating time is capacity in amp-hours divided by average current.

Battery run time equals amp-hour capacity divided by average current, for example 100 Ah over 5 A is 20 hours.
Describe this graphic in words

A 100 amp-hour battery feeds a load drawing 5 amps average. A gold formula bar reads hours equals capacity in amp-hours divided by average current in amps. The worked example gives 20 hours, shown on a timeline. Dimmed boxes warn about the inverted fraction and resistance.

This is a teaching note. A 100 amp-hour battery feeding a 5 A average load lasts about 100 / 5 = 20 hours. The units work out: amp-hours divided by amps gives hours.

In practice usable capacity is lower than the label, but the relationship stays the same.

Why the other choices are wrong

  • A. Inverted: this gives hours per amp-hour.
  • B. Internal resistance is not how runtime is calculated.
  • D. Resistance divided by current is volts, not time.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D10

Why is a switching type power supply less expensive and lighter than an equivalent linear power supply?

Show the answer and why

Answer C. The high frequency inverter design uses much smaller transformers and filter components for an equivalent power output

A switching supply is lighter and cheaper because its high-frequency design uses much smaller transformers and filter components.

Switchmode regulator block diagram with pulse waveform, and why high frequency makes it smaller.
Describe this graphic in words

A block diagram shows DC input feeding a switch, then an L-C filter that averages the pulses into smooth DC output, with a control block adjusting the pulse width from a sample of the output. A pulse train with a dashed average line shows that wider pulses raise the output. Two cards compare a 60 hertz linear supply with large parts against a switching supply at tens to hundreds of kilohertz with much smaller parts.

This is a teaching note. Transformer and filter size shrink as frequency goes up. A linear supply works at 60 Hz and needs large iron-core parts, while a switcher works at tens or hundreds of kHz.

It still needs an output filter, and it does not recover unused AC power.

Why the other choices are wrong

  • A. It does need an output filter.
  • B. Heat sink size is not the main saving.
  • D. It does not recover power from the unused AC cycle.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D11

What is the purpose of an inverter connected to a solar panel output?

Show the answer and why

Answer D. Convert the panel’s output from DC to AC

A solar panel inverter converts the panel DC output to AC.

A solar panel produces DC and an inverter converts it to AC.
Describe this graphic in words

A blue solar panel icon sends a flat DC line into a gold box labeled inverter. A gold sine wave leaves the box as the AC output. A dimmed note lists the wrong choices.

This is a teaching note. Panels produce DC. An inverter turns it into AC for household loads or for feeding the grid.

Smoothing ripple, holding voltage steady, or preventing discharge are done by filters, charge controllers and blocking diodes.

Why the other choices are wrong

  • A. A panel makes DC and has no AC ripple to reduce.
  • B. A charge controller or regulator maintains voltage.
  • C. A blocking diode prevents discharge.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D12

What is the dropout voltage of a linear voltage regulator?

Show the answer and why

Answer C. Minimum input-to-output voltage required to maintain regulation

Dropout voltage is the minimum input-to-output voltage a linear regulator needs to stay in regulation.

Series and shunt linear regulators compared, with a worked pass-element dissipation and dropout example.
Describe this graphic in words

Two block diagrams compare linear regulators. The series regulator has a pass element in the path to the load, controlled by an error amplifier and a reference. The shunt regulator has a series resistor and a shunt element across the load that loads the source. Two panels below show that a series regulator with 13.8 volts in, 5 volts out and 1 amp dissipates 8.8 watts, and that a 5 volt regulator with 1 volt dropout needs at least 6 volts in.

This is a teaching note. For a 5 V regulator with a 1 V dropout, the input must be at least 6 V. Below that, the output falls with the input.

Low-dropout (LDO) regulators have a small value, such as a few hundred millivolts.

Why the other choices are wrong

  • A. It is not about power dissipation.
  • B. That describes line regulation.
  • D. That describes load regulation.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D13

Which of the following calculates power dissipated by a series linear voltage regulator?

Show the answer and why

Answer C. Voltage difference from input to output multiplied by output current

Power in a series linear regulator is the input-to-output voltage difference times the output current.

Series and shunt linear regulators compared, with a worked pass-element dissipation and dropout example.
Describe this graphic in words

Two block diagrams compare linear regulators. The series regulator has a pass element in the path to the load, controlled by an error amplifier and a reference. The shunt regulator has a series resistor and a shunt element across the load that loads the source. Two panels below show that a series regulator with 13.8 volts in, 5 volts out and 1 amp dissipates 8.8 watts, and that a 5 volt regulator with 1 volt dropout needs at least 6 volts in.

This is a teaching note. The pass transistor drops the difference and carries the load current. For a 13.8 V input, 5 V output and 1 A load, that is (13.8 - 5) x 1 = 8.8 W of heat.

Output voltage times output current is the power delivered to the load, not wasted.

Why the other choices are wrong

  • A. Input power includes what reaches the load.
  • B. Volts divided by amps is resistance.
  • D. That is the load power.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D14

What is the purpose of connecting equal-value resistors across power supply filter capacitors connected in series?

Show the answer and why

Answer D. All these choices are correct

All of the choices are correct. The equal resistors balance the voltage, bleed the capacitors and provide a minimum load.

Equal resistors across series filter capacitors balance the voltage, bleed the capacitors and give a minimum load.
Describe this graphic in words

Two filter capacitors in series across a high-voltage supply, each with an equal resistor in gold. Without the resistors the voltage could split 500 and 300 volts; with them it is about 400 volts each. Three gold numbered roles are listed: balance, bleed and minimum load, so all of the choices are correct.

This is a teaching note. Electrolytic capacitors in series do not share voltage evenly because their leakage differs, so equal resistors across each force an even split. When power is removed the resistors also discharge the capacitors, which is a safety benefit.

They also draw a small steady current, which is a minimum load on the supply. As an example, two 450 V electrolytics in series on a 800 V supply could split unevenly, say 500 V and 300 V, and the first would be overstressed. A 100 kohm resistor across each forces roughly 400 V on each, and the same resistors bleed the capacitors down after power-off.

Why the other choices are wrong

  • A. True, but not the only purpose.
  • B. True, but not the only purpose.
  • C. True, but not the only purpose.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E7D15

What is the purpose of a step-start circuit in a high-voltage power supply?

Show the answer and why

Answer D. To allow the filter capacitors to charge gradually

A step-start circuit lets the filter capacitors charge gradually, and it also protects the switch contacts.

A step-start circuit puts a resistor in series at turn-on to limit inrush current, then bypasses it.
Describe this graphic in words

A block diagram of the AC line, switch, a resistor with a relay bypass, and the power supply filter capacitors. Below it a graph compares a red huge inrush spike with a gold gentle charging curve. A gold box says the filter capacitors charge gradually and the switch contacts are protected from arcing.

This is a teaching note. Empty filter capacitors look like a short circuit at turn-on and cause a huge inrush current. A step-start circuit puts a resistor in series first, then bypasses it after a moment, so the capacitors charge gradually. That is the purpose the keyed answer names.

Choice C is also true as a consequence, because a big inrush current is what can arc across the switch or relay contacts. The pool keys D as the purpose, since limiting the capacitor charging is the direct action and the arcing protection follows from it. A step-start does not change the output voltage or compensate for line variations.

Why the other choices are wrong

  • A. Dual-voltage output is a different feature.
  • B. Compensating for line voltage is regulation.
  • C. This is also a true effect: limiting inrush does protect the switch or relay contacts from arcing. It is a consequence of the charging limit rather than the circuit's direct action, so the pool keys D.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.