Which of the following factors most affects the accuracy of a frequency counter?
Show the answer and why
Answer B. Time base accuracy
The accuracy of a frequency counter depends mostly on its time base.
Describe this graphic in words
A chain starts at a gold crystal oscillator time base, which sets the gate time for the counter, which produces the reading. An example shows a time base that is 1 ppm off giving an error of about 144 Hz at 144 MHz. Three dimmed boxes reject the attenuator, dividers and logic temperature coefficient.
This is a teaching note. A counter counts cycles of the input during a gate time that comes from its internal crystal oscillator, the time base. If the crystal is off by one part per million, every reading is off by one part per million.
For example, a counter with a time base that is 1 ppm off reading a 144.000000 MHz signal is wrong by about 144 Hz. Attenuators, decade dividers and logic temperature behavior do not change the count.
Why the other choices are wrong
- A. The input attenuator only scales the input level and does not change the count.
- C. Dividers count exactly. They do not add a frequency error.
- D. Logic temperature coefficient does not set accuracy, whereas the time base crystal does.
Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.