E4A01

Which of the following limits the highest frequency signal that can be accurately displayed on a digital oscilloscope?

Show the answer and why

Answer A. Sampling rate of the analog-to-digital converter

A digital scope can only show signals up to a limit set by the sampling rate of its analog-to-digital converter.

A 9 MHz sine sampled at 10 megasamples per second is drawn by the scope as a false 1 MHz wave.
Describe this graphic in words

A thin blue 9 MHz sine wave is sampled by white dots spaced 100 nanoseconds apart. The dots do not follow the fast wave; they fall on a much slower gold 1 MHz sine wave, which is what the oscilloscope displays. Text notes that the highest displayable frequency is under half the sampling rate.

This is a teaching note. A digital oscilloscope measures the input voltage at discrete instants and then draws the dots. The Nyquist limit says you need more than two samples per cycle to represent a signal at all, so the converter's sampling rate sets a hard ceiling on the highest frequency that can be shown. In practice scopes want several samples per cycle to draw a believable shape.

As a worked example, a scope sampling at 100 megasamples per second cannot properly display anything above 50 MHz, and a clean display of a sine wave needs a good deal less than that.

Why the other choices are wrong

  • B. There is no "reference frequency" that limits the display. The converter's reference is a voltage, and it sets the amplitude range, not the frequency limit.
  • C. Q is a property of tuned circuits, not of how a scope samples a signal.
  • D. Only the sampling rate is correct, so "all of these" fails.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A02

Which of the following parameters does a spectrum analyzer display on the vertical and horizontal axes?

Show the answer and why

Answer B. Signal amplitude and frequency

A spectrum analyzer plots signal amplitude up the vertical axis and frequency along the horizontal axis.

Spectrum analyzer display with level on the vertical axis and frequency on the horizontal axis, showing two tall tones and smaller intermodulation peaks.
Describe this graphic in words

A spectrum analyzer screen with level in dBm on the vertical axis and frequency on the horizontal axis, both marked in gold. Two tall blue peaks are the two wanted test tones. Beside them, shorter red peaks show the third-order products at 2f1 minus f2 and 2f2 minus f1, and still smaller fifth-order products further out. Text explains the two-tone test of an SSB transmitter.

This is a teaching note. Where an oscilloscope shows voltage against time, a spectrum analyzer shows how much signal there is at each frequency. Each carrier, sideband or spur appears as a peak at its own frequency, with its height showing its level, usually in dBm.

SWR is measured by an antenna analyzer or a bridge, not plotted on the axes of a spectrum analyzer.

Why the other choices are wrong

  • A. Amplitude against time is what an oscilloscope displays.
  • C. SWR against frequency is what an antenna analyzer sweep shows, not a spectrum analyzer.
  • D. SWR against time is not a standard display of a spectrum analyzer.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A03

Which of the following test instruments is used to display spurious signals and/or intermodulation distortion products generated by an SSB transmitter?

Show the answer and why

Answer B. Spectrum analyzer

A spectrum analyzer is the instrument that shows spurious signals and intermodulation products from an SSB transmitter.

Spectrum analyzer display with level on the vertical axis and frequency on the horizontal axis, showing two tall tones and smaller intermodulation peaks.
Describe this graphic in words

A spectrum analyzer screen with level in dBm on the vertical axis and frequency on the horizontal axis, both marked in gold. Two tall blue peaks are the two wanted test tones. Beside them, shorter red peaks show the third-order products at 2f1 minus f2 and 2f2 minus f1, and still smaller fifth-order products further out. Text explains the two-tone test of an SSB transmitter.

This is a teaching note. Spurs and intermodulation products sit at frequencies other than the wanted signal. Only an instrument that plots level against frequency can show where they are and how far down they are from the main signal.

The usual test is to feed the transmitter two audio tones and watch the output on a spectrum analyzer, where the distortion products appear as extra peaks beside the two wanted tones.

Why the other choices are wrong

  • A. A differential resolver is not a test instrument for displaying RF spectra.
  • C. A logic analyzer looks at digital signal states over time, not RF spectrum.
  • D. A network analyzer measures how a circuit responds to a stimulus, such as gain and reflection, rather than showing what a transmitter emits.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A04

How is compensation of an oscilloscope probe performed?

Show the answer and why

Answer A. A square wave is displayed, and the probe is adjusted until the horizontal portions of the displayed wave are as nearly flat as possible

You compensate a scope probe by viewing a square wave and adjusting the probe until the flat tops are as flat as possible.

Three square-wave traces: under-compensated with rounded corners, correct with flat tops, over-compensated with spikes.
Describe this graphic in words

Three panels each show a square wave on the oscilloscope. The left one has rounded, sluggish corners (under-compensated). The middle one, highlighted in gold, has flat tops and square corners and is the correct adjustment. The right one has spikes at the leading corners (over-compensated). The trimmer on the probe is adjusted until the wave looks like the middle panel.

This is a teaching note. A 10x probe is a voltage divider made of a resistor and a capacitor, and the capacitive part must match the scope input capacitance. If it does not, the divider ratio changes with frequency. The scope's built-in calibrator provides a square wave for this check.

If the tops of the square wave slope or have a spike or a droop, the probe is over or under compensated. You turn the small trimmer on the probe until the corners are square and the tops are flat.

Why the other choices are wrong

  • B. Maximum amplitude of a sine wave does not tell you the divider is balanced across frequency.
  • C. Probe compensation is about the frequency response of the divider, not timing accuracy.
  • D. A DC check only tests the resistive part of the divider, and compensation is the capacitive match.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A05

What is the purpose of using a prescaler with a frequency counter?

Show the answer and why

Answer D. Reduce the signal frequency to within the counter's operating range

A prescaler divides the signal frequency down so that a low-frequency counter can count it.

A 1.2 GHz signal passes through a divide-by-100 prescaler to become 12 MHz for the counter.
Describe this graphic in words

A left to right chain shows a 1.2 GHz input going into a gold prescaler box labeled divide by 100. Its 12 MHz output feeds a low-frequency counter, and the display scales the result back up by 100. Three dimmed boxes below mark the wrong choices.

This is a teaching note. A frequency counter's input circuits only work up to some maximum frequency. A prescaler is a fast divider placed ahead of the counter that divides by a fixed number such as 10 or 100.

For example, a 1.2 GHz signal through a divide-by-100 prescaler becomes 12 MHz, which a modest counter can handle. The counter then multiplies the result back (or the display is scaled) to show the real frequency.

Why the other choices are wrong

  • A. Amplifying a weak signal is done by an input amplifier, not a prescaler.
  • B. A prescaler divides frequency, it does not multiply it.
  • C. Preventing oscillation is not what a prescaler is for.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A06

What is the effect of aliasing on a digital oscilloscope when displaying a waveform?

Show the answer and why

Answer A. A false, jittery low-frequency version of the waveform is displayed

Aliasing on a digital scope shows up as a false, jittery, lower-frequency version of the real waveform.

A 9 MHz sine sampled at 10 megasamples per second is drawn by the scope as a false 1 MHz wave.
Describe this graphic in words

A thin blue 9 MHz sine wave is sampled by white dots spaced 100 nanoseconds apart. The dots do not follow the fast wave; they fall on a much slower gold 1 MHz sine wave, which is what the oscilloscope displays. Text notes that the highest displayable frequency is under half the sampling rate.

This is a teaching note. When the input frequency is more than half the sampling rate, the samples land at points that also fit a slower wave. The scope has no way to tell the difference, so it draws that slower wave, and because the true signal drifts against the sample clock the picture often wanders or jitters.

For example, a 9 MHz signal sampled at 10 megasamples per second looks like a 1 MHz signal. Using a higher sampling rate avoids the problem. Slowing the time per division setting often lowers the sampling rate, which is a common way to cause aliasing.

Why the other choices are wrong

  • B. DC offset is a vertical setting and is not changed by aliasing.
  • C. Vertical calibration depends on the input amplifier, not on sample timing.
  • D. Aliasing still shows a trace. It is just a wrong one.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A07

Which of the following is an advantage of using an antenna analyzer compared to an SWR bridge?

Show the answer and why

Answer B. Antenna analyzers compute SWR and impedance automatically

Compared with an SWR bridge, an antenna analyzer works out SWR and impedance for you.

An SWR bridge gives forward and reflected power while an antenna analyzer calculates SWR and impedance itself.
Describe this graphic in words

Two panels compare instruments. The left SWR bridge needs a transmitter and shows forward and reflected power only. The right gold antenna analyzer has its own source and receiver and calculates SWR, complex impedance and resonant frequency across a sweep. Two dimmed boxes show that it does not tune the antenna and does not show modulation.

This is a teaching note. An SWR bridge needs a transmitter and gives only a forward and reflected power reading. An antenna analyzer has its own low-power signal source and receiver, and calculates SWR, complex impedance and often resonant frequency directly across a sweep of frequencies.

It does not tune the antenna for you, and it does not display a modulation envelope. That is an oscilloscope job.

Why the other choices are wrong

  • A. An analyzer measures what is wrong. You still have to adjust the antenna yourself.
  • C. A time-varying modulation envelope is shown on an oscilloscope, not an antenna analyzer.
  • D. Only one of the choices is correct.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A08

Which of the following is used to measure SWR?

Show the answer and why

Answer D. All these choices are correct

Directional wattmeters, vector network analyzers and antenna analyzers can all be used to measure SWR.

Directional wattmeter, vector network analyzer and antenna analyzer all lead to an SWR measurement.
Describe this graphic in words

Three blue boxes on the left name the directional wattmeter, the vector network analyzer and the antenna analyzer. Arrows from all three converge on a gold SWR box, labeled all of these, showing each instrument can measure SWR.

This is a teaching note. A directional wattmeter reads forward and reflected power, and SWR follows from their ratio. A vector network analyzer measures S11 (reflection), from which SWR is calculated. An antenna analyzer displays SWR directly.

Since each of the three can do it, "all of these" is the right choice.

Why the other choices are wrong

  • A. This is correct but incomplete, because the other two instruments also measure SWR.
  • B. This is correct but incomplete, because the other two instruments also measure SWR.
  • C. This is correct but incomplete, because the other two instruments also measure SWR.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A09

Which of the following is good practice when using an oscilloscope probe?

Show the answer and why

Answer A. Minimize the length of the probe's ground connection

Keeping the probe ground lead as short as possible is good scope practice.

A long scope probe ground lead causes ringing while a short ground lead gives a clean edge.
Describe this graphic in words

Two panels show the same step edge on a scope. With a long ground lead the red trace overshoots and rings. With a short ground lead, shown in gold, the edge is clean. Two dimmed boxes explain that a high-impedance probe and DC coupling are not the problem statements.

This is a teaching note. A long ground lead adds inductance in series with the probe tip. At higher frequencies that inductance and the probe capacitance ring, and you see overshoot and ringing that are not really in the circuit. A short spring ground or ground clip right at the test point removes most of it.

The other statements are backward or untrue. A high-impedance probe is actually the one you want so it does not load the circuit, and a DC-coupled input can be used to look at AC signals, with the scope's AC coupling available when needed.

Why the other choices are wrong

  • B. A high-impedance probe loads the circuit under test very little, so it is fine for low-impedance circuits and is the usual choice for any circuit.
  • C. DC coupling passes AC as well, so it can be used for AC circuits. It simply also shows any DC.
  • D. Only the short ground lead statement is good practice.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A10

Which trigger mode is most effective when using an oscilloscope to measure a linear power supply’s output ripple?

Show the answer and why

Answer D. Line

Line trigger locks the scope to the power-line frequency, which makes it most effective for viewing linear supply ripple.

Line triggering locks the scope to the 60 Hz line so the 120 Hz ripple pattern holds steady.
Describe this graphic in words

A 60 Hz sine wave carries gold trigger marks at the start of each line cycle. Below it, a 120 Hz ripple waveform has two bumps per line cycle and stays locked to the trigger. A gold box says line trigger keeps the ripple steady. Three dimmed boxes reject single shot, edge and level triggering.

This is a teaching note. The ripple on a linear supply is produced by the rectifier and filter capacitor charging on each half cycle of the AC line, so it repeats at 120 Hz in the US (twice the 60 Hz line frequency). Triggering from the line itself holds that repeating pattern steady on the screen, since the ripple stays locked to the line.

Edge or level triggering off the ripple can wander because the ripple is small and noisy. Single-shot is for capturing one event.

Why the other choices are wrong

  • A. Single-shot captures one event and is not suited to a repeating ripple pattern.
  • B. Edge triggering on a small noisy ripple can be unstable, and line triggering is the better match.
  • C. Level triggering on a small noisy ripple can be unstable, and line triggering is the better match.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.

E4A11

Which of the following can be measured with an antenna analyzer?

Show the answer and why

Answer D. All these choices are correct

An antenna analyzer can measure velocity factor, cable length and the resonant frequency of a tuned circuit.

An antenna analyzer can measure velocity factor, cable length and resonant frequency.
Describe this graphic in words

A blue antenna analyzer box on the left sends three arrows to three gold results: velocity factor, cable length and resonant frequency of a tuned circuit. The label all of these marks the keyed answer.

This is a teaching note. An antenna analyzer can find where a circuit is resonant by sweeping and looking for the dip in reactance. For a coax stub, you can find the frequency where it shows quarter-wave behavior. That frequency and the physical length give you the cable's velocity factor. With a known velocity factor the same method gives you electrical cable length.

Since all three are possible, "all of these" is correct.

Why the other choices are wrong

  • A. This is possible, but so are the other two.
  • B. This is possible, but so are the other two.
  • C. This is possible, but so are the other two.

Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.