What is meant by the blocking dynamic range of a receiver?
Show the answer and why
Answer A. The difference in dB between the noise floor and the level of an incoming signal that will cause 1 dB of gain compression
Blocking dynamic range is the dB difference between the noise floor and the level of a signal that causes 1 dB of gain compression.
Describe this graphic in words
A vertical scale of input level in dBm. A blue line marks the noise floor at minus 130 dBm. A red line marks the level at which the receiver gain compresses by 1 dB, at minus 20 dBm. A gold bar between them is labelled 110 dB blocking dynamic range.
This is a teaching note. As an input signal grows strong enough, the receiver front end starts to compress, and the gain drops. The point where the gain has fallen 1 dB is the compression point. The span from the noise floor up to that level is the range over which the receiver works normally.
For example, a noise floor of -130 dBm and 1 dB compression at -20 dBm gives a blocking dynamic range of 110 dB.
Why the other choices are wrong
- B. This describes an FM capture situation, not blocking dynamic range.
- C. This is closer to a different measure that uses the third-order intercept.
- D. This describes the third-order intermodulation dynamic range.
Rule text checked against the official source on November 17, 2026. This is a study aid; the linked rule is what governs.