T9B01

Which of the following connectors should be carefully taped for weather protection when used outdoors?

Show the answer and why

Answer D. All these choices are correct

All of these connectors need careful weather protection outdoors.

Table comparing PL-259, BNC and Type N connectors by coupling, best use and weather protection.
Describe this graphic in words

A table lists three connectors with columns for coupling, use and outdoors. The PL-259 is screw thread, for HF and VHF, not weatherproof. The BNC is bayonet, for handhelds and test gear, not weatherproof. The Type N is screw thread, for UHF and microwave above 400 MHz, weather resistant but still taped. Gold marks the PL-259 HF/VHF use and the Type N above 400 MHz use, and a note says any coax connector outdoors needs weather sealing.

PL-259, BNC and Type N connectors can all let moisture in unless the joint is sealed. The PL-259 and its SO-239 jack are threaded with no real gasket, and the BNC has no weather seal at all. The Type N has an O-ring gasket and is the most weather resistant of the three, but outdoors it should still be taped.

Water inside a connector corrodes the contacts, wicks into the braid and raises loss. The usual fix is a layer of self-amalgamating (self-fusing) tape, then a layer of UV-resistant vinyl tape over it, with a drip loop in the cable so water runs off before it reaches the joint. This is a teaching note.

Why the other choices are wrong

  • A. The PL-259 does need protection, but so do the BNC and Type N, so this answer is incomplete.
  • B. The BNC does need protection, but so do the PL-259 and Type N, so this answer is incomplete.
  • C. The Type N does need protection outdoors, but so do the PL-259 and BNC, so this answer is incomplete.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B02

What is the most common impedance of coaxial cables used in amateur radio?

Show the answer and why

Answer B. 50 ohms

The most common amateur coax impedance is 50 ohms.

End view of coax showing the center conductor, insulation, braided shield and jacket, with the 50-ohm calculation.
Describe this graphic in words

A circular cross-section shows from the center out: a gold center conductor, blue insulation, a gray braided shield and a dark outer jacket, with a legend naming each. A gold panel gives the impedance formula 138 divided by the square root of the dielectric constant times log10 of D over d, then works an example with polyethylene (2.25) and D/d of 3.5, giving 92 x 0.54, about 50 ohms.

Most amateur transceivers and antennas are designed for a 50-ohm system, so the common amateur coax types, such as RG-58, RG-213 and LMR-400, are all 50 ohms. A feed line that matches the radio's output impedance keeps SWR low and avoids extra loss.

A coax cable's impedance is set by its geometry and insulation: the ratio of the shield's inside diameter to the center conductor's diameter, and the dielectric constant. For polyethylene insulation (dielectric constant 2.25), a diameter ratio of about 3.5 gives 138 / 1.5 x log10(3.5) = 92 x 0.54 = about 50 ohms. This is a teaching note.

Why the other choices are wrong

  • A. 8 ohms is a typical loudspeaker impedance, not a coax cable.
  • C. 600 ohms is typical of open-wire feed line, which is a balanced line and not coax.
  • D. 12 ohms is not a standard coax impedance. Real coax comes in values such as 50 ohms for radio and 75 ohms for TV and cable.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B03

Why is coaxial cable the most common feed line for amateur radio antenna systems?

Show the answer and why

Answer A. It is easy to use and requires few special installation considerations

Coax is the most common feed line because it is easy to use and needs few special installation considerations.

In coax the signal's fields are contained between the center conductor and the shield. That means it can run next to metal, along a tower or mast, through conduit or underground without upsetting the antenna system, and it connects to most amateur gear with a single standard connector.

Other lines can beat coax in one respect, but each has a catch. Open-wire (ladder) line has lower loss, yet it must be kept clear of other objects and usually needs a balanced tuner. Hardline has very low loss, but it is stiff, expensive and harder to terminate. Coax gives up a little in loss for convenience. This is a teaching note.

Why the other choices are wrong

  • B. Open-wire line and hardline have less loss than ordinary coax, so coax does not have the least loss.
  • C. Hardline and other large cables handle more power than common coax.
  • D. Coax is not always the cheapest, and low cost is not the main reason for its popularity. Ease of installation is.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B04

What is the major function of an antenna tuner (antenna coupler)?

Show the answer and why

Answer A. It matches the antenna system impedance to the transceiver's output impedance

An antenna tuner matches the antenna system impedance to the transceiver's output impedance.

Block diagram: transceiver, antenna tuner, feed line, antenna, with the tuner presenting 50 ohms to the radio.
Describe this graphic in words

Four boxes in a row connected by arrows: transceiver (wants 50 ohms), antenna tuner (impedance match, highlighted in gold), feed line (coax) and antenna (any impedance). Beneath, a left panel for the radio side says it sees 50 ohms, SWR 1:1, and a right panel for the antenna side says it might be 150 ohms (3:1). A note says the tuner does not change the antenna, remove feed line loss or switch antennas.

A transmitter is built to work into about 50 ohms. If the antenna and feed line present a different impedance, the transmitter's protection circuits reduce power. The tuner sits between the radio and the feed line and transforms the impedance seen by the radio back to about 50 ohms.

Worked example: an antenna system presenting 150 ohms to a 50-ohm radio has an SWR of 3:1. The tuner makes the radio see 1:1 and it delivers full power. Note that the mismatch still exists on the feed line between the tuner and the antenna, so the tuner does not change the antenna's pattern, reduce feed line loss or pick up stations. This is a teaching note.

Why the other choices are wrong

  • B. A tuner does not tune in stations. Selecting and receiving signals is the receiver's job.
  • C. Using one antenna for transmit and receive is handled by the transceiver's antenna relay, not the tuner.
  • D. Choosing among antennas is the job of an antenna switch.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B05

What happens as the frequency of a signal in coaxial cable is increased?

Show the answer and why

Answer D. The loss increases

Coax loss increases as frequency increases.

Bar chart of approximate coax loss per 100 feet at 146 and 440 MHz for four cable types.
Describe this graphic in words

Two groups of horizontal bars compare approximate loss per 100 feet. At 146 MHz: RG-58 about 6 dB, RG-213 about 2.5 dB, an LMR-400 type about 1.5 dB and 1/2-inch hardline about 0.5 dB. At 440 MHz every bar is longer: 11, 4.5, 2.7 and 0.9 dB. The hardline bars are gold. A worked example says 6 dB of loss turns 100 W into about 25 W and that figures are typical catalog values.

At higher frequencies the current crowds toward the surface of the conductors (skin effect) and the insulation absorbs more energy, so a given cable wastes more of the signal. Loss is stated in dB per 100 feet, and it goes up with frequency for every coax type.

Worked example: 100 ft of RG-58 loses roughly 6 dB at 146 MHz, which leaves only about 25 percent of the power. At 440 MHz the same cable loses roughly 11 dB, leaving under 10 percent. That is why long UHF runs use larger, lower-loss cable (dB figures are typical catalog values and vary by maker). This is a teaching note.

Why the other choices are wrong

  • A. Characteristic impedance depends on the cable's construction, not on frequency.
  • B. Loss goes up, not down, as frequency increases.
  • C. Characteristic impedance does not increase with frequency.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B06

Which of the following connector types is most suitable as an RF connector for frequencies above 400 MHz?

Show the answer and why

Answer B. Type N

Type N connectors are most suitable above 400 MHz.

Table comparing PL-259, BNC and Type N connectors by coupling, best use and weather protection.
Describe this graphic in words

A table lists three connectors with columns for coupling, use and outdoors. The PL-259 is screw thread, for HF and VHF, not weatherproof. The BNC is bayonet, for handhelds and test gear, not weatherproof. The Type N is screw thread, for UHF and microwave above 400 MHz, weather resistant but still taped. Gold marks the Type N use above 400 MHz and the PL-259 HF and VHF use.

The Type N is a constant-impedance, weather-resistant connector designed for UHF, microwave and higher. Its geometry holds 50 ohms right through the connector, so it adds little mismatch or loss at 400 MHz and above.

The PL-259, commonly called a UHF connector, is not constant-impedance. It works well at HF and VHF but its performance gets poorer as frequency rises into UHF. This is a teaching note.

Why the other choices are wrong

  • A. The PL-259 is intended for HF and VHF and performs poorly at higher frequencies because it is not constant-impedance.
  • C. RS-213 is not a connector. RG-213 is a type of coax cable.
  • D. The DB-25 is a 25-pin computer data connector, not an RF connector.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B07

Which of the following is true of PL-259 type coax connectors?

Show the answer and why

Answer C. They are commonly used at HF and VHF frequencies

PL-259 connectors are commonly used at HF and VHF frequencies.

Table comparing PL-259, BNC and Type N connectors by coupling, best use and weather protection.
Describe this graphic in words

A table lists three connectors with columns for coupling, use and outdoors. The PL-259 is screw thread, for HF and VHF (highlighted in gold), not weatherproof. The BNC is bayonet, for handhelds and test gear, not weatherproof. The Type N is screw thread, for UHF and microwave above 400 MHz, weather resistant but still taped.

The PL-259, also called a UHF connector, mates with the SO-239 jack. It is a standard on many HF and VHF radios and antennas because it is cheap, strong and handles high power at those frequencies.

It is not constant-impedance, so it is a poor choice for microwave and weak at UHF. It also has no gasket, so it is not watertight and needs taping outdoors. The connection is made by screwing on a threaded collar; the quarter-turn bayonet connector is the BNC. This is a teaching note.

Why the other choices are wrong

  • A. The PL-259 is not preferred for microwave work. It is not constant-impedance, and Type N or SMA connectors are used there.
  • B. It has no gasket or seal, so it is not watertight. Outdoor PL-259 joints need tape.
  • D. The PL-259 is a threaded connector. The BNC is the bayonet type.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B08

Which of the following is a source of loss in coaxial feed line?

Show the answer and why

Answer D. All these choices are correct

All of these cause loss in coax.

Water in a connector or cable adds loss and, over time, corrodes the shield and contacts. Every connector in the line adds a small loss and another chance for moisture or a poor joint, and a corroded or water-filled connector can add much more. A high SWR adds loss as well because power travels back and forth along the cable, so the loss is added on each trip along the cable.

Because each of the three listed causes is real, "all of these" is correct. Loss also depends on the cable type, its length and the frequency. This is a teaching note.

Why the other choices are wrong

  • A. Water intrusion does cause loss, but so do high SWR and extra connectors, so this answer is incomplete.
  • B. High SWR does add loss in the cable, but so do water and extra connectors, so this answer is incomplete.
  • C. Multiple connectors do add loss, but so do water and high SWR, so this answer is incomplete.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B09

What can cause erratic changes in SWR?

Show the answer and why

Answer B. Loose connection in the antenna or feed line

A loose connection in the antenna or feed line can cause erratic SWR changes.

An intermittent connection changes the load the transmitter sees from moment to moment, so the SWR reading jumps around, especially when the wind moves the antenna or cable. A loose or corroded connector, a broken solder joint or a bad element joint are typical culprits.

To find it, turn off the transmitter and check the connectors and element joints for looseness and corrosion. Weather, modulation and strong nearby signals do not change the match of the antenna system. This is a teaching note.

Why the other choices are wrong

  • A. A distant or local thunderstorm may add noise, but it does not change the antenna system's SWR in this way.
  • C. Over-modulation causes distortion and splatter, not SWR changes.
  • D. A strong local station can overload a receiver, but it does not change the SWR of your antenna system.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B10

What is the electrical difference between RG-58 and RG-213 coaxial cable?

Show the answer and why

Answer C. RG-213 cable has less loss at a given frequency

RG-213 has less loss than RG-58 at a given frequency.

Bar chart of approximate coax loss per 100 feet at 146 and 440 MHz for four cable types.
Describe this graphic in words

Two groups of horizontal bars compare approximate loss per 100 feet. At 146 MHz: RG-58 about 6 dB, RG-213 about 2.5 dB, an LMR-400 type about 1.5 dB and 1/2-inch hardline about 0.5 dB. At 440 MHz the bars are longer: 11, 4.5, 2.7 and 0.9 dB. A worked example says 6 dB of loss turns 100 W into about 25 W, and the figures are typical catalog values.

RG-213 is a thicker cable with a larger center conductor and a larger dielectric, so it loses less signal per 100 feet and handles more power. Both are 50-ohm cables, so the electrical difference you notice is loss.

Worked example: at 146 MHz, 100 ft of RG-58 loses roughly 6 dB, so 100 W in leaves about 25 W. The same run of RG-213 loses roughly 2.5 dB, leaving about 56 W. The dB figures are typical catalog values and vary by maker. This is a teaching note.

Why the other choices are wrong

  • A. There is a significant difference: RG-213 has much lower loss and handles more power.
  • B. Standard RG-58 has a single braided shield, as does RG-213. The difference between them is the size and construction, not the shield count.
  • D. It is the other way around. The larger RG-213 handles higher power than RG-58.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B11

Which of the following types of feed line has the lowest loss?

Show the answer and why

Answer C. Air-insulated hardline

Air-insulated hardline has the lowest loss.

Bar chart of approximate coax loss per 100 feet at 146 and 440 MHz for four cable types.
Describe this graphic in words

Two groups of horizontal bars compare approximate loss per 100 feet. At 146 MHz: RG-58 about 6 dB, RG-213 about 2.5 dB, an LMR-400 type about 1.5 dB and 1/2-inch hardline about 0.5 dB. At 440 MHz: 11, 4.5, 2.7 and 0.9 dB. The hardline bars are gold, showing it has the lowest loss at both frequencies.

Hardline has a solid or corrugated metal shield and an air or foam dielectric around a large center conductor, so its loss is very low, even at VHF and UHF. Flexible coax, whether 50 or 75 ohm, has a thin braided shield and a solid or foam dielectric, and it loses much more.

Worked example: at 146 MHz, 100 ft of RG-58 loses about 6 dB while 1/2-inch hardline loses about 0.5 dB, leaving about 89 percent of the power. Open-wire line can be lower still, but it is not one of the choices here. Multi-conductor unbalanced cable is not a low-loss feed line. This is a teaching note.

Why the other choices are wrong

  • A. Flexible 50-ohm coax has a lot more loss than hardline.
  • B. Multi-conductor unbalanced cable is not a low-loss RF feed line.
  • D. Flexible 75-ohm coax has a lot more loss than hardline, and its impedance does not suit most radio gear.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.

T9B12

What is standing wave ratio (SWR)?

Show the answer and why

Answer A. A measure of how well a load is matched to a transmission line

SWR is a measure of how well a load is matched to a transmission line.

A 50-ohm line feeding different loads, with the SWR and share of power reflected.
Describe this graphic in words

A sketch shows a transmitter, a 50-ohm feed line with a gold forward power arrow, and a load. Below, a table lists loads and results: 50 ohms gives 1:1 and 0 percent reflected, 75 ohms gives 1.5:1 and 4 percent, 100 ohms (or 25 ohms) gives 2:1 and 11 percent (highlighted in gold), and 150 ohms (or 16.7) gives 3:1 and 25 percent. Formulas for SWR and reflected power are given.

SWR is 1:1 when the load matches the line and rises as the mismatch grows. For a resistive load, it is the larger of the load and line impedances divided by the smaller. A mismatch reflects part of the power back toward the transmitter, and the standing waves on the line are what SWR measures.

Worked example: a 50-ohm line feeding a 100-ohm load has an SWR of 100 / 50 = 2:1. The reflected share of power is ((2 - 1) / (2 + 1))^2 = 1/9, about 11 percent. A 3:1 SWR reflects 25 percent. This is a teaching note.

Why the other choices are wrong

  • B. The ratio of amplifier power output to input is amplifier gain, not SWR.
  • C. Efficiency is a different ratio, output power compared with input power, and does not describe SWR.
  • D. SWR does not measure the quality of your ground connection.

Rule text checked against the official source on November 5, 2026. This is a study aid; the linked rule is what governs.